Pressure Systems 9022 Manuale Utente Pagina 106

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 105
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual
www.PressureSystems.com
3 - 76
Some special rack-mounted module types (e.g., 9816) also add rack, cluster, and slot
parameters to the response above. These additional parameters are added following the
pwrst’ parameter.
This uniform network query response allows a client host program to identify, configure,
and use any suitable group of modules (for the task at hand) by simply opening a TCP/IP connection
between itself and each available module needed.
Example:
! Query all module(s) on the network.
“psi9000”
Response(s):
200.201.7.207, 0-e0-8d-1-7-cf, 1999, 9022, 2.32, 0, 1, 9000, 192.0.0.0, 0,
1, 0x0
Vedere la pagina 105
1 2 ... 101 102 103 104 105 106 107 108 109 110 111 ... 193 194

Commenti su questo manuale

Nessun commento